加工定制:是 | 类型:超声波探伤仪 | 品牌:Olympus/奥林巴斯 |
型号:MS 5800E | 测量范围:详见资料 | 分辨率:详见资料 |
尺寸:详见资料mm | 重量:5kgkg |
Eddy current testing is a noncontact method used to inspect nonferromagnetic tubing. This technique is suitable for detecting and sizing metal discontinuities such as corrosion, erosion, wear, pitting, baffle cuts, wall loss, and cracks in nonferrous materials.
MultiScan MS?5800E Key Features
The ultrasonic IRIS option is used to inspect a wide range of materials, including ferrous, nonferrous, and nonmetallic tubing. This technique detects and sizes wall loss resulting from corrosion, erosion, wear, pitting, cracking, and baffle cuts. Olympus digital IRIS inspection technology is used extensively as a prove-up technique for remote field testing, magnetic flux leakage, and eddy current inspections.
General | Power | 120 VAC or 220 VAC ±10%, automatic selection, 48 Hz to 63 Hz |
---|---|---|
Size (excluding handle) | 45 cm x 30 cm x 22 cm | |
Weight | Maximum weight with all modules installed: 12.8 kg | |
Environment | -20°C to 45°C for ambient operation; -20°C to 70°C storage; 95% relative humidity, noncondensing | |
Computer interface | 100Base-T Fast Ethernet | |
Eddy Current Testing | Probe inputs | Four independent differential inputs, and up to 64 multiplexed inputs (16 time slots) with MUX-PKG-MS (U8780060) |
ECT channels | 16 simultaneously (4 inputs x 4 frequencies); 256 in super-multiplexed mode (with 16 time slots) | |
Number of frequencies | Up to eight frequencies | |
Frequency range | Adjustable from 20 Hz to 6 MHz | |
Acquisition rate | 40 kHz per channel (in conventional mode); 14 kHz divided by the number of time slots (in multiplexed mode) | |
Supported probes | The universal connector supports all standard differential and absolute bobbin, impedance, transmit-receive, and rotating probes. (Adaptor cable might be required.) | |
Probe balancing | True electronic probe balancing. A separate external reference probe is not required for absolute channels. | |
Output voltage | 20 Vp-p per generator (2 outputs) | |
Output current | 1 A (peak) | |
Real-time alarms | Eight independent alarms (raw channels only) | |
Encoders | Two quadrature encoders and digital inputs | |
Remote Field Testing, Near Field, and Magnetic Flux Leakage | Probe inputs | Four independent inputs for RFT/NFT Four independent inputs for MFL |
RFT/NFT channels | 16 simultaneously (4 inputs x 4 frequencies); 64 in multiplexed mode for NFT (4 inputs x 16 time slots) and eight for RFT (4 inputs x 2 time slots) | |
MFL channels | Four simultaneously 64 in multiplexed mode (4 inputs x 16 time slots) | |
Number of frequencies | Up to four frequencies (RFT only) | |
Frequency range | Adjustable from 20 Hz to 250Eddy Current Testing kHz | |
Acquisition rate | 40 kHz per channel (in conventional mode); 14 kHz divided by the number of time slots (in multiplexed mode) | |
Supported probes | Supports any differential and absolute probes with a single exciter, dual exciters, dual pickup, near field, and magnetic flux leakage. (Adaptor cable might be required.) | |
Probe balancing | True electronic probe balancing | |
Output voltage | 20 Vp-p per generator (2 outputs) |
MS 5800E ;MS 5800E 探伤仪 奥林巴斯 MS 5800E
MS 5800E ;MS 5800E 探伤仪 奥林巴斯 MS 5800E
MS 5800E ;MS 5800E 探伤仪 奥林巴斯 MS 5800E